DVA331.XXX vibration displacement sensors with current output DVA331.XXX vibration displacement sensors with current output

Designed for measurement the range of vibration displacement in emergency protection systems (EPS);

Consist of a sealed housing, which are integrated acceleration sensor and conversion board;

Sensor versions:

  • DVA331.104 - triangular case, all-in-one cable connection, 3-screw mount;
  • DVA331.132 - triangular case, cable with 2PM connector, mount on 3 screws;
  • DVA331.164 - triangular case, TIK-KXX connector on cable, mount for 3 screws;
  • DVA331.214 - cylindrical small-sized housing, TIK-KXX connector on the body (analogue of MIL-C-5015), mounting on a stud;
  • DVA331.252 - cylindrical small-sized housing, connection to the terminal block, mounting on a stud;
  • DVA331.714 - rectangular case, TIK-KXX connector on the body (analogue of MIL-C-5015), 1 screw mount;

To install the sensor assembly DVA331.214 / DVA331.252 uses the standard stud M8 / M10 / M12; for the special order it is possible to supply the studs with any thread, including inch;  

DVA331.214 allows the use of cable assemblies with MIL connector from imported sensors;

Output signal type – 4-20 mA

Add to compare list
DVA334.XXX vibration displacement sensors with digital output DVA334.XXX vibration displacement sensors with digital output

Designed for measurement the range of vibration displacement in emergency protection systems (EPS);

Consist of a sealed housing, which are integrated acceleration sensor and conversion board;

Sensor versions:

  • DVA334.104 - triangular case, all-in-one cable connection, 3-screw mount;
  • DVA334.164 - triangular case, TIK-KXX connector on cable, mount for 3 screws;
  • DVA334.214 - cylindrical small-sized housing, TIK-KXX connector on the body (analogue of MIL-C-5015), mounting on a stud;
  • DVA334.714 - rectangular case, TIK-KXX connector on the body (analogue of MIL-C-5015), 1 screw mount;

To install the sensor assembly DVA334.214 uses the standard stud M8 / M10 / M12; for the special order it is possible to supply the studs with any thread, including inch;

DVA334.214 allows the use of cable assemblies with MIL connector from imported sensors

Output signal type – RS-485 (Modbus RTU)

Add to compare list
IKV-1-3-1 vibration measuring channel IKV-1-3-1 vibration measuring channel

Designed to measure the vibration displacement range in diagnostic and emergency protection systems (EPS)*;

Consisting of a DS-x eddy-current transducer, an AS 131 transducer (in a connection box), or an AS 1312 transducer in a connector.

Can be used on compressor equipment;

Channel versions:

  • IKV-1-3-1 ver. A - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 131 converter, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-3-1 ver. B - DS-0 (DS-1, DS-2, DS-3) ver. 02 eddy-current transducer, AS 1312 converter in the socket, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-3-1 ver. E - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 131 converter (with display), (connection box, TIK-BIS.121.0X0X safety barrier)**.

Output signal type:

  • 4-20 mA (for ver. A, B, E);
  • 0-10 V (for ver. E);
  • digital output (for ver. E).

*By default, the channel is set to 40X metal

**Available as an option

Add to compare list
IKV-1-3-1 vibration measuring channel cryogenic version IKV-1-3-1 vibration measuring channel cryogenic version

The indicator is designed to measure vibration displacement span, rotational speed, axial shift and detecting marks in vibration monitoring systems of rotary machines at low temperatures;

It consists of a DS-1 eddy-current transducer and AV131-V converter (in the connecting box).

Output signal type – 4-20 mA, 0-10 V;

Add to compare list
New product
IKV-1-4-1 vibration measuring channel IKV-1-4-1 vibration measuring channel

Designed to measure the axial shift in the emergency protection system (EPS)*;

It consists of a DS-x eddy-current transducer, an AS 141 converter (in a connection box), or an AS 1412 converter in a connector. Depending on the version, indication blocks are used to output the measured parameters;

Channel versions:

  • IKV-1-4-1 ver. A - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 141 converter, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1 ver. B - DS-0 (DS-1, DS-2, DS-3) ver. 02 eddy-current transducer, AS 1412 converter in the socket, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1 ver. V - DS-0 (DS-1, DS-2, DS-3) ver. 02 eddy-current transducer, AS 1412 converter in the socket, indication block, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1 ver. E - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 141 converter (with display), (connection box, TIK-BIS.121.0X0X safety barrier)**.

Output signal type:

  • 4-20 mA (for ver. A, B, V, E);
  • 0-10 V (for ver. E);
  • digital output (for ver. E).

*By default, the channel is set to 40X metal

**Available as an option

Add to compare list
IKV-1-4-4 vibration measuring channel IKV-1-4-4 vibration measuring channel

Designed to measure axial displacement of industrial equipment units*;

Area of application - control of axial displacement of working mechanisms in power engineering and machine-building industry;

It consists of a DS-x eddy-current transducer and the AS 144 transducer (installed in the connection box).

Channel versions:

  • IKV-1-4-4 ver. A - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 144 converter, connection box**.

Output signal type - -1...-17 V;

*By default, the channel is set to 40X metal

**Available as an option

Add to compare list
IKV-1-4-1.1 vibration measuring channel IKV-1-4-1.1 vibration measuring channel

Designed to measure speed (factory mode) and phase angle (set by jumper) in emergency protection systems (EPS)*;

It consists of a DS-x eddy-current transducer, an AS 141 converter (in a connection box), or an AS 1412 converter in a connector. Depending on the version, indication blocks are used to output the measured parameters;

Channel versions:

  • IKV-1-4-1.1 ver. A - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 141 converter, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1.1 ver. B - DS-0 (DS-1, DS-2, DS-3) ver. 02 eddy-current transducer, AS 1412 converter in the socket, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1.1 ver. V - DS-0 (DS-1, DS-2, DS-3) ver. 02 eddy-current transducer, AS 1412 converter in the socket, indication block, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1.1 ver. E - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 141 converter (with display), (connection box, TIK-BIS.121.0X0X safety barrier)**.

Output signal type:

  • 4-20 mA (for ver. A, B, V, E);
  • 0-10 V (for ver. E);
  • digital output (for ver. E).

*By default, the channel is set to 40X metal

**Available as an option

Add to compare list