RU EN

DVA484.XXX three-axis sensors with digital output

DVA484.XXX three-axis sensors with digital output

Designed to measure vibration velocity, vibration acceleration, vibration displacement* in three coordinates, as well as angles of inclination and temperature;

*The vibration acceleration signal, passing through the mathematical processing block, is converted into vibration velocity and vibration displacement signals. For each of the parameters it is also possible to calculate the amplitude, mean square value and span.

In the sealed case there are integrated acceleration sensor and conversion board;

Sensor versions:

  • DVA484.104 - triangular case, all-in-one cable connection, 3-screw mount;
  • DVA484.164 - triangular case, TIK-KXX connector on cable, mount for 3 screws;
  • DVA484.214 - cylindrical small-sized housing, TIK-KXX connector on the body (analogue of MIL-C-5015), mounting on a stud;
  • DVA484.714 - rectangular case, TIK-KXX connector on the body (analogue of MIL-C-5015), 1 screw mount.

Features:

  • All calculations are performed in real time, with an update interval of 10ms registers;
  • Measurement error of vibration parameters is not more than 5% in the main frequency range;
  • Additional error of not more than 2.5%;
  • Built-in temperature sensor allows you to control the temperature with an accuracy of ±2 °C;
  • Determination of the angles of inclination of each axis with an accuracy of 1°.

Output signal type – RS-485 (Modbus RTU)

Additional photos

Reviews

Related equipment

TIK-PLC.991.11
controller
TIK-BIS
safety barriers
TIK-REG
recorder
Cable cutting tool

specifications

Metrological parameters

  • Conversion coefficient, mV*s2/m / Range of indications of amplitude of vibration acceleration, m/s2
    1 / 0-25
    1 / 0-40
    1 / 0-100
  • Conversion coefficient, mA/μm / Range of indications of amplitude of vibration displacement, μm
    1 / 0-25
    1 / 0-40
    1 / 0-100
  • Conversion coefficient, mA*s/mm / Range of indications of amplitude of vibration velocity, mm/s
    1 / 0-25
    1 / 0-40
    1 / 0-100
  • Operating frequency range, Hz
    2-1000
    3-1000
    5-1000
    10-1000

Interface

  • Output signal type
    RS-485
  • Supply voltage range, V
    10-24
  • Protocol
    Modbus RTU

Explosion protection

  • Kind
    intrinsically safe circuit
  • Marking
    0Ex ia IIC T6...T2 Ga X / PO Ex ia I Ma X
    2Ex nA IIC T6...T2 Gc X
  • Connection
    through TIK-PLC.991.11 controller;
    through TIK-BIS.414.XXXX or
    TIK-BIS.616.XXXX safety barriers

Design parameters

  • Version
    all-in-one cable connection (DVA484.104)
    TIK-KXX connector on cable (analogue of MIL) (DVA484.164)
    TIK-KXX connector on the body (analogue of MIL-C-5015) (DVA484.214, DVA484.714)
  • Overall dimensions, mm
    Ø39.25x43.5 (DVA484.104)
    Ø39.25x36 (DVA484.164)
    Ø26.5x57.5 (DVA484.214)
    39х54x24.5 (DVA484.714)
  • Weight, kg, not more than
    0.1 (DVA484.1XX)
    0.13 (DVA484.214)
    0.25 (DVA484.714)
  • Mounting type
    screw M4x21 (M4x28) 3 pcs. (DVA484.1XX)
    stud M8 / M10 / M12 1 pc. (DVA484.214)
    screw M6 1 pc. (DVA484.714)
  • Protection class
    IP65/IP68

Operating parameters

  • Operating temperature range, ºС
    -40...+80 (climatic version H)
    -60...+80 (climatic version X)
    -196...+80 (climatic version K)

Reliability parameters and manufacturer's guarantees

  • MTBF, hours, not less than
    100 000
  • Warranty service life, months
    24
  • Service life, years, not less than
    20
  • Time between verifications
    2 years
Service center