RU EN

DVA121.3XX vibration velocity sensors with current output

DVA121.3XX vibration velocity sensors with current output

Designed to measure the root mean square (RMS) value of vibration velocity in emergency protection systems (EPS);

Consist of a sealed housing, which is a acceleration sensor and conversion board;

Easily replace imported analogues;

Thanks to the version with connection terminal block inside the case (DVA121.352), the incoming cable is quickly and conveniently mounted;

For DVA121.352 - order available cable glands 3 types or nut;

Output signal type – 4-20 mA;


RPE "TIK" developed alternative DVA141.2XX vibration sensors, made in a smaller case and with a MIL connector:

  • To replace the DVA121.342 vibration sensor with the DVA141.214, you will need to replace the mating connector - 2-pin instead of 4;
  • DVA121.352 and DVA141.252 vibration sensors are complete analogs, connected via a terminal block.

Additional photos

Reviews

specifications

Metrological parameters

  • Conversion coefficient, mA*s/mm / Range of indications of RMS vibration velocity, mm/s
    1.6 / 0-10
    1.259 / 0-12.7
    0.8 / 0-20
    0.64 / 0-25
    0.63 / 0-25.4
    0.533 / 0-30
    0.4 / 0-40
    0.32 / 0-50
    0.315 / 0-50.8
    0.267 / 0-60
    0.2 / 0-80
    0.16 / 0-100
  • Operating frequency range, Hz
    2-1000
    3-1000
    5-1000
    10-1000

Interface

  • Output signal type
    "current loop" 4-20 mA
  • Supply voltage range, V
    10-24
  • Polarity of the connection of vibration sensor
    arbitrary

Explosion protection

  • Kind
    intrinsically safe circuit
  • Marking
    0Ex ia IIC T6...T2 Ga X / PO Ex ia I Ma X
    2Ex nA IIC T6...T2 Gc X
  • Connection
    through TIK-PLC 112 controller
    through TIK-BIS safety barrier

Design parameters

  • Version
    with connector 2РМГ housing (DVA121.342)
    connection to the terminal block inside the housing (DVA121.352)
  • Overall dimensions, mm
    Ø26.5x75 (DVA121.342)
    47x95 (DVA121.352)
  • Weight, kg, not more than
    0.24
  • Mounting type
    stud M8x1/M10x1/M12x1,
    M10x1.25, 1/4" NPT, 1/2" NPT, 3/4" NPT,
    1/4" 28 UNF, 3/8"-16 UNC
  • Protection class
    IP65

Operating parameters

  • Operating temperature range, ºС
    -40...+80 (climatic version H, for 0Ex ia IIC T5...T6 Ga X)
    -60...+80 (climatic version X, for 0Ex ia IIC T5...T6 Ga X)
    -40...+80 (for PO Ex ia I Ma X)

Reliability parameters and manufacturer's guarantees

  • MTBF, hours, not less than
    100 000
  • Warranty service life, months
    24
  • Service life, years, not less than
    20
  • Time between verifications
    2 years
Service center